Insulation Calculator
Work out how much attic insulation you need — the target R-value for your climate zone, the depth to install, how many bags to buy and the installed cost. Enter your attic area, climate zone and existing insulation, and the insulation calculator does the rest.
It works for blown fibreglass, fibreglass batts, cellulose and closed-cell spray foam, and it rounds bags up, because you cannot buy part of a bag. Use the worked example and the bags table below to check your numbers before you order.

Insulation Calculator
Enter your attic area, climate zone and material to work out the R-value, depth, bags and cost.
Zone 5 default is R-49 — the 2024 IECC minimum for Zones 4–8. ENERGY STAR’s uninsulated-attic target for Zones 4–8 is R-60.
Formula
Bags = (area x (1 + waste %)) / (1,200 / target R-value)
- R-value measures resistance to heat flow — higher is better, and R-values add up.
- ENERGY STAR attic targets (uninsulated): R-30 in Zone 1, R-49 in Zones 2-3, R-60 in Zones 4-8.
- Adding over 3-4 inches of existing insulation in Zones 4-8: add R-49.
- The 2024 IECC minimum for Zones 4-8 is R-49 — the worked example uses R-49 for that reason.
- Depth = target R-value / material R-value per inch (R-49 fibreglass batt at R-3.2/inch is about 15.3 inches).
- Bags are rounded up — you cannot buy part of a bag.
- The 10% waste covers cutting and settling.
Worked Example
A 1,000 sq ft attic in Zone 5 is being insulated to R-49 with fibreglass batts (R-3.2 per inch), with a 10% waste allowance and an installed cost of $1.40 per sq ft.
- Step 1: Area with waste = 1,000 x 1.10 = 1,100 sq ft.
- Step 2: Coverage per bag = 1,200 / 49 = 24.5 sq ft.
- Step 3: Bags = 1,100 / 24.5 = 44.9 -> 45 bags.
- Step 4: Depth = 49 / 3.2 = 15.3 inches.
Answer: 45 bags of fibreglass batts, 15.3 inches deep, for R-49 (about $1,400 installed at $1.40/sq ft).
Bags by Target R-Value
The table below is for a 1,000 sq ft attic with a 10% waste allowance.
| Target R-value | Coverage per bag | Bags needed |
|---|---|---|
| R-38 | 31.6 sq ft/bag | 35 bags |
| R-49 | 24.5 sq ft/bag | 45 bags |
| R-60 | 20.0 sq ft/bag | 55 bags |
FAQs
ENERGY STAR recommends R-60 for a fully uninsulated attic in Zones 4-8, or adding R-49 over 3-4 inches of existing insulation. The 2024 IECC minimum for Zones 4-8 is R-49.
Depth = R-value / R-per-inch. R-49 fibreglass batt at R-3.2/inch is about 15.3 inches; blown fibreglass needs about 20 inches for the same R-value.
Area with waste / coverage per bag at your target R-value, rounded up. A 1,000 sq ft attic at R-49 needs 45 bags.
Loose-fill cellulose settles 10-20% over its lifetime, which is why the 10% waste allowance matters — start a little high and you stay near target years later.